Monitoring for preservation of heritage structures

The complete solution for monitoring of historic buildings, structures and landmarks

 
Our historic buildings, heritage structures and ancient landmarks are treasured both culturally and architecturally. Their preservation is important. Yet nearby construction activities or re-development of these assets increases the risk we damage them, this can also occur when being used differently to the original design intention. Historic structures become susceptible to deformation over time, leading to potentially increasing safety concerns and rising maintenance costs. 

Deformation monitoring provides real-time information about movements, allowing data-driven decisions to prolong the life of structures, ensure their protection, and contribute to proactive reductions of maintenance. 

Total Monitoring is the combination of data from geodetic monitoring sensors (total stations, GNSS or levels) with geotechnical and environmental sensors (tilt sensors, crack or strain gauges, weather stations, etc.) and interferometric radar. It delivers the complete picture about occurring events aiding a greater understanding of the influence on structures. Using innovative scanning technologies for automated monitoring, the Leica MS60 MultiStation can obtain data in a non-intrusive way, without disturbing the surface of monitored objects. 

Why monitoring is essential for historic structures: 

  1. Monitoring structural health is critical where structures are susceptible to deterioration over time and when adjacent activities affect their stability, reducing the structural integrity and increasing safety concerns during continued operation and preservation.
  2. During any maintenance or renovation, the buildings or landmarks are subjected to additional forces limiting the structure’s resilience, deformation monitoring aids teams to understand the effects of their works and ensure that they prolong the useable life of the structures without damaging them. Thus, knowing that any restoration works are safe activities to progress.
  3. Protection during nearby construction development of these assets is critical. Disturbance of ground during nearby construction causes movements which can introduce increased stress on the structure, causing deformation or distortions. Early warning of these can prevent damage to the structure.
  4. Documenting historical change, such as cracks or alignments of objects is crucial for structural monitoring records associated with the change during its lifetime. This can aid the preservation for future generations and also it can provide a history of change if a disaster occurs.
  5. Environmental change can have a huge impact on older structures, which were not designed to modern standards or expectations. Severe weather events, erosion over time or natural shifting of the Earth’s surface, may cause instability which can significantly affect or damage structures. Monitoring these events and the impact they have is essential for preservation and for future continued use.

 

This video presents typical generic examples of monitoring installations on a heritage structure, yet every monitoring project requires its own specifically assessed and designed monitoring system thus specialists should be consulted before any installation.




Примеры использования

Monitoring a heritage hotel in the historic centre of Cologne

Preserved as a historic building, the original façade and staircase of the Dom Hotel had to be preserved while partial demolition of its internal structure was carried out.
Preserved as a historic building, the original façade and staircase of the Dom Hotel had to be preserved while partial demolition of its internal structure was carried out.

Monitoring historic Harvard Stadium

Find out how monitoring helps guide Harvard to make appropriate decisions on the life-safety of the famous Harvard stadium.
Find out how monitoring helps guide Harvard to make appropriate decisions on the life-safety of the famous Harvard stadium.

Monitoring the structural health of hangars

Monitoring the Royal Canadian Air Force Warren Truss Hangars’ wooden structure
Monitoring the Royal Canadian Air Force Warren Truss Hangars’ wooden structure
Программные продукты

Leica GeoMoS

Гибкое программное решение для автоматического обнаружения деформаций.
Гибкое программное решение для автоматического обнаружения деформаций.

Leica GeoMoS Edge

Программное обеспечение для мониторинга обеспечивает автономное управление датчиками и бесперебойную регистрацию данных в полевых условиях.
Программное обеспечение для мониторинга обеспечивает автономное управление датчиками и бесперебойную регистрацию данных в полевых условиях.

Leica GeoMoS Now!

Анализируйте и визуализируйте данные мониторинга независимо от вашего местаположения.
Анализируйте и визуализируйте данные мониторинга независимо от вашего местаположения.
Оборудование

Leica Nova TM50

Самый точный и надежный тахеометр для мониторинга с технологией визуализации.
Самый точный и надежный тахеометр для мониторинга с технологией визуализации.

Leica ComBox60

An intelligent autonomous device for communication and power management.
An intelligent autonomous device for communication and power management.

Geotechnical Sensors

Automated geotechnical sensor measurement & data acquisition
Automated geotechnical sensor measurement & data acquisition

Leica Nova MS60

Универсальный тахеометр с возможностью сканирования и самообучения, с возможностью ГНСС подключения и цифровой визуализацией
Универсальный тахеометр с возможностью сканирования и самообучения, с возможностью ГНСС подключения и цифровой визуализацией

Leica LS15 & LS10

Digital levels with industry-leading accuracy.
Digital levels with industry-leading accuracy.

Leica GMX910

GNSS receiver with integrated antenna for monitoring.
GNSS receiver with integrated antenna for monitoring.


Got questions? We´ve got the answers!

Let us support you